Prairie plains - oil and gas

AER Regulations on Hydrogen Sulfide (H2S) in Produced Gas and Liquids in Alberta, Canada

Hydrogen sulfide (H2S), a toxic and corrosive gas, is a significant concern in Alberta’s oil and gas industry, particularly in sour gas wells found in formations like the Montney. The Alberta Energy Regulator (AER) enforces strict regulations to manage H2S in produced gas and liquids, ensuring public safety, environmental protection, and operational compliance. This article provides an in-depth look at AER regulations, covering key directives, H2S release rate assessments, sampling and analysis, flaring and venting limits, well abandonment, and compliance mechanisms.

Overview of H2S in Alberta’s Oil and Gas Industry

H2S, known as sour gas, is present in many Alberta hydrocarbon reservoirs, with concentrations exceeding 23% in fields like Crossfield East, Okotoks, Ricinus, and Ricinus West. Defined by the AER as any well with H2S content above 0.01%, sour gas poses risks of respiratory harm, sudden collapse, and environmental damage if mismanaged. AER regulations, outlined in Directives 056, 017, 060, and 020, address these risks through comprehensive requirements for assessment, measurement, and mitigation.

Key AER Directives Governing H2S

The AER regulates H2S under the Oil and Gas Conservation Act and related legislation through several directives:

  • Directive 056: Energy Development Applications and Schedules – Mandates H2S release rate assessments for wells with potential H2S content.
  • Directive 017: Measurement Requirements for Oil and Gas Operations – Specifies sampling and analysis procedures for H2S in gas and liquids.
  • Directive 060: Upstream Petroleum Industry Flaring, Incinerating, and Venting – Sets limits on flaring and venting H2S-containing gas.
  • Directive 020: Well Abandonment – Outlines procedures for abandoning sour wells to prevent H2S leakage.

H2S Release Rate Assessments (Directive 056)

Under Section 7.7.15 of Directive 056, operators must submit an H2S Release Rate Assessment before drilling Category C, D, or E wells (based on H2S potential). This assessment determines the Emergency Planning Zone (EPZ) for public safety and notification.

  • Purpose: Evaluates maximum potential H2S release to ensure safe operations.
  • Key Fields: High H2S concentrations occur in areas like Crossfield East and Okotoks, managed by operators such as Shell Canada and TAQA North.
  • Requirements: Operators submit data on H2S concentrations, reservoir properties, and mitigation plans, following the Canadian Association of Petroleum Producers (CAPP) Guideline 2012-0008 for standardized calculations.

Non-compliance with assessment requirements triggers penalties under Directive 019: Compliance Assurance.

Sampling and Analysis Requirements (Directive 017)

Directive 017, Section 8, details sampling and analysis protocols for accurate H2S measurement in gas and liquids, critical for royalty calculations and safety.

  • Sampling Frequency: Table 8.3 in Section 8.4 specifies frequencies, with high-volume streams requiring more frequent sampling and low-volume streams potentially exempt with AER approval.
  • Analysis Procedures: Operators must analyze samples for H2S and hydrocarbon components. Recombined gas/condensate analysis ensures accurate liquid allocation, avoiding royalty underreporting.
  • Non-Compliance: Inaccurate sampling or outdated analyses can lead to non-compliance under Directive 019, affecting volumetric reporting and royalties.

For liquids-rich wells (liquid-to-gas ratio >0.28 m³ per 10³ m³), Directive 017 permits proration measurement for multiwell pads, as per AER Bulletin 2014-20, to reduce costs while ensuring accurate H2S measurement.

Flaring, Incinerating, and Venting Limits (Directive 060)

Directive 060 regulates flaring, incineration, and venting of H2S-containing gas to minimize environmental and health impacts, prioritizing gas conservation.

  • Flaring and Venting Limits:
    • Solution Gas Flaring: Capped at 670 million m³ annually (50% of 1996 baseline).
    • Combined Flaring and Venting: Limited to 900 m³ per day per site.
    • Venting Limits: Total venting capped at 15,000 m³ or 9,000 kg of methane per month per site; routine venting limited to 3,000 m³ or 1,800 kg of methane.
    • Gas Plants: Plants processing 1 billion m³ annually are limited to 0.2% of raw gas receipts or 5 million m³ per year for flaring, incineration, and venting.
  • H2S-Specific Requirements:
    • Venting is prohibited if gas volumes support combustion.
    • For wells with H2S >1%, operators must notify residents within 3 km 24 hours before planned flaring; for H2S <1%, the radius is 1.5 km.
    • Combustion must achieve high efficiency to convert H2S to SO₂, requiring a minimum gas energy content of 20 MJ/m³.
  • Equipment-Specific Limits:
    • Pneumatic devices installed post-January 1, 2022, must control vent gas; pre-2022 devices require low-vent retrofits.
    • Compressor seals must be tested annually, with reciprocating compressors limited to <0.83 m³/hr/throw by January 1, 2023.

The AER encourages continuous improvement in reducing H2S emissions through performance-based regulations.

Well Abandonment for Sour Wells (Directive 020)

Directive 020 specifies abandonment procedures for sour wells to prevent H2S leakage, with stringent requirements for critical sour wells.

  • Critical Sour Well Requirements:
    • Classified based on H2S content and release potential per Directive 056.
    • Require longer cement plugs and additional cementing of perforations to block H2S migration.
  • Suspension Timelines:
    • Sour wells must be suspended within six months of inactivity, versus 12 months for non-sour wells.
    • High-risk sour wells require permanent plugs or risk reduction measures.

These measures protect groundwater and surface environments from H2S leakage.

Compliance and Enforcement

The AER enforces H2S regulations via inspections, audits, and penalties under Directive 019. Non-compliance may result from inaccurate H2S sampling, exceeding flaring/venting limits, or failing to meet assessment or abandonment requirements. Operators must report H2S data via Petrinex, as outlined in ST3: Alberta Energy Resource Industries Monthly Statistics.

H2S in the Montney Formation Context

In the Montney Formation, sour gas is present in deeper reservoirs, requiring compliance with AER regulations for safe production. Operators in liquids-rich areas like Kakwa must adhere to Directive 017 for H2S measurement and Directive 060 for flaring management to mitigate risks.

Environmental and Safety Considerations

H2S’s toxicity necessitates robust safety measures:

  • High combustion efficiency to convert H2S to SO₂.
  • Ventilation and containment for H2S leaks in confined spaces.
  • Operator training and explosion-proof equipment in H2S-prone areas.

Future Outlook and Regulatory Evolution

Aligned with federal methane reduction goals, the AER’s H2S regulations may evolve to address new technologies like carbon capture and hydrogen production. Revisions to Directives 017 and 060 aim to enhance emissions management, ensuring Alberta’s regulations remain equivalent to federal standards.

Conclusion

The AER’s regulations on H2S in produced gas and liquids are vital for safe and sustainable oil and gas operations in Alberta. Through Directives 056, 017, 060, and 020, the AER ensures rigorous H2S management, protecting public safety and the environment. As the industry evolves, these regulations will adapt to support Alberta’s energy transition while maintaining operational integrity.

Sources